I

NFRARED

B

ROILER

OWNER’S MANUAL 1199790 REV 0 (6/14)

PAGE 14

OF 46

I

NSTALLATION

5. Bolt the frames of the sections together.
6. Connect the front manifolds using the pipe-union.
7. Attach the trim-strip between the section tops.
8. Install the continuous front-rail, if ordered.
9. Slide control knobs onto their shafts (to operate the sections during the installation procedure), but do not yet
reattach valve panels or front-panel trim pieces.

S

TEP

5:

C

ONNECT

E

LECTRICITY (

O

VEN

B

ASE)

A wiring diagram is located behind on the rear of the oven. Be sure that the input voltage and phase match the

requirements shown on the serial plate.
Oven-bases ordered with a 115V, 60Hz, single-phase electrical rating are factory-supplied with a three-wire cord with

a three-prong plug that fits any standard three-prong grounded receptacle. Each standard oven requires a 15 ampere

supply, while each convection oven requires a 20 ampere supply.
Oven-bases ordered with a 208/236V, 60Hz, single- or three-phase electrical rating are factory-equipped with a two-pole

terminal block located behind cover plate located on the rear of the unit. To connect the supply wires, remove the cover

plate. Route the supply wires and the grounding wire through the strain relief fitting to the terminal block. Insert the supply

wires, one each, into the two poles of the terminal block and tighten the screws. Insert the ground wire into the grounding

lug and tighten the screw. Re-attach the cover plate.
Three phase units are wired as above, using only two supply wires. The third wire is not used and must be properly

terminated.
All units are shipped wired as specified by factory order. Conversion between single-phase and three-phase can be

accomplished by referring to phase loading and line amperes chart on the wiring diagram for wire size and ampere

requirements.

S

TEP

6

:

C

ONNECT

E

LECTRICITY (

B

ROILER)

Wiring diagram location will vary depending on the model:
- For broilers with an oven base the wiring diagram is located on the rear of the oven base.
- For free standing broilers the wiring diagram is located behind the filter (See Figure 1)
Be sure that the input voltage and phase match the requirements shown on the serial plate.

Broilers ordered with a 115V, 60Hz, single-phase electrical rating are factory-supplied with a three-wire cord with a three-

prong plug that fits any standard three-prong grounded receptacle. Each standard oven requires a 15 ampere supply.
Broilers ordered with a 208/240V, 60Hz, single phase electircal rating are factory supplied with a three wire cord. A plug,

(not provided) must be installed.
An optional electic element rated at 3000 watts, 208/240V, is available in the wiring oven. ** This is indicated on the serial

plate by the prefix EW. A seperate electric supply, 208/240V, single phase, 20 AMP must be connected to the leads in a

terminal box at the rear, near the top of the broiler. This installation must confirm with local codes, or in their absence, with

the NATIONAL ELECTRICAL CODE ANSI/NFPA 70-Latest Edition. Canadian installation must comply with CSA C22.1

Canadian Electrical Code Parts I and II.

S

TEP

7

:

C

ONNECT

G

AS

S

UPPLY

If the Southbend equipment is being installed at over 2,000 feet altitude and that information was not specified when

ordered, contact the appropriate authorized Southbend Service Representative or the Southbend Service Department.

Failure to install with proper orifice sizing will result in poor performance and may void the warranty.
Southbend equipment is design-certified for operation on natural or propane gases. The units are shipped configured and

adjusted for the type of gas specified by the purchaser, which is indicated on the serial plate (see Figure 1). Connect the

equipment ONLY to the type of gas for which it is configured and adjusted.