OPERATION

INTRODUCTION

This model is a heavy-duty piece of equipment designed for
continuous use. It incorporates automatic controls to regulate
the cycling of the refrigeration system.

CONTROLS AND INDICATORS

Table 2.1 - Controls and Indicators

NAME

TYPE

FUNCTION

Low Pressure Switch

Contact Points

Cycles the refrigerator system (automatic)

Suction Valve

Manual Plunger Valve

Isolate suction at the compressor

Discharge Valve

Manual Plunger Valve

Isolate discharge line at receiver

Power Control Switch (On/Off)

Contact Points

Terminates all of the electrical into and past
the supply cord

Thermostat

Contact Points

Cycles the refrigerator system (automatic)

Defrost Timer

1

Contact Points

Controls scheduled evaporator coil defrosting

Solenoid Valve

Automatic Plunger

Shuts off refrigerant flow