OPERATION

PREPARATION FOR AN EXTENDED PERIOD
OF INACTIVITY

This unit is designed for continued use at automatically
cycled intervals. However, in the event of an extended shut
down, both the mechanical refrigeration system and the food
storage compartment system must be serviced.

Table 2.4 - Shut Down Procedures for an Extended Period

Operation

Results

1. Fully close discharge valve at the receiver.

2. Fully close suction valve at the compressor.

3. Disconnect power supply.

4. Clean and wipe dry the food storage compartment.

Compressor will pump liquid refrigerant from system
to receiver.

This will isolate the refrigerant between the two valves.

De-energizes the system.

This will reduce the odor buildup during shut down.