Pecifications, Lectricity, Upply – Southbend SL-Series User Manual

Page 4

Advertising
background image

OWNER’S MANUAL 1199740 REV 1 (10/14)

PAGE

4

OF 44

G

AS

C

ONVECTION

O

VENS

S

PECIFICATIONS

NOTICE

Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc.

states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation

requirements for equipment. Therefore, installations should comply with all local codes.

Southbend reserves the right to change specifications and product design without notice. Such revisions do not entitle

the buyer to corresponding changes, additions, or replacements for previously purchased equipment.

This product is intended for commercial use only, not for household use.

The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,

ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2,

as applicable, including:

1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any

pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).

2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve `

during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45

kPa).

E

LECTRICITY

S

UPPLY

Convection ovens require connection to a supply of electricity. The appliance, when installed, must be electrically ground-

ed in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or

the Canadian Electrical Code, CSA C22.2, as applicable. An electrical diagram is located on the side of the control panel

assembly. Electrical diagrams can also be found in this manual beginning on page 38.

Power Option

Power Type

# of Ovens Maximum Amps

120/60/1

120 Volts, 60 Hz, Single Phase

Single-Deck

Double-Deck

8.9

17.8

208/60/1or3

190-219 Volts, 60 Hz, Single or Three Phase

Single-Deck

Double-Deck

4.8

9.6

240/60/1or3

220-240 Volts, 60 Hz, Single or Three Phase

Single-Deck

Double-Deck

4.3

8.6

240/50/1or3

208-240 Volts, 50 Hz, Single or Three Phase

Single-Deck

Double-Deck

6.5

13.0

Ovens ordered with the 120V power option are equipped with one or two power cords with a standard 120V single-phase

plug with a ground prong. Single-deck ovens will have one power cord; double-deck ovens will have two.

Ovens with other power options have a terminal block on the rear of the oven that must be wired to the power supply.

Depending on how the power supply is connected to the terminal block, the oven can operate on either single-phase of

three-phase power.