Djustments – Southbend B-Series User Manual

Page 31

Advertising
background image

G

AS

C

ONVECTION

O

VENS

OPERATOR’S MANUAL 1181887 REV 9 (10/14)

PAGE 31

OF 44

A

DJUSTMENTS

WARNING

ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS

EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF COMMERCIAL COOKING EQUIPMENT.

HOWEVER, TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR RELIABLE

SERVICE, DEPENDABLE ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY PARTS.

NOTICE

Warranty will be void and the manufacturer is relieved of all liability if service work is performed by other than a qualified

technician, or if other than genuine Southbend replacement parts are installed.

L

UBRICATION

The door chains and sprockets have been lubricated at the factory with high temperature “Never Seeze” lubricant. After

each six months of usage, lubricate the door chains and sprockets with the same type of lubricant.

Motor lubrication information can be found on permanent label located on motor.

A

DJUSTING

G

AS

P

RESSURE

R

EGULATOR

The pressure regulator is factory set at 4.0” W.C. for natural gas and 11” W.C. for propane gas. To check the manifold

pressure:

1. Turn all thermostats and burner valves to “OFF” position.

2. Turn main gas valve to entire unit off.

3. Remove valve panels and locate 1/8” plug in manifold.

4. Remove plug and install a fitting appropriate to connect a manometer.

5. Turn on main gas to unit and light pilots.

6. Turn all burners and ovens to full “ON” position and read manometer.

7. If manometer does not read 4.0” W.C. for natural gas, or 11” W.C. for propane gas, adjust regulator (if gas pressure is

O.K. go to Step 10).

8. Remove cap from top of regulator.

9. With a screwdriver rotate regulator adjustment screw clockwise to increase, or counterclockwise to decrease, pressure

until manometer shows correct reading.

10. Repeat steps 1 and 2.

11. Remove manometer fitting and replace plug in manifold.

12. Repeat step 5.

13. Replace valve panels.

A

DJUSTMENTS

Advertising
This manual is related to the following products: