E

LECTRIC

C

ONVECTION

O

VENS

OPERATOR’S MANUAL 1181958 REV 5 (4/14)

PAGE

4

OF 47

S

PECIFICATIONS

NOTICE

The appliance, when installed, must be electrically grounded and comply with local codes, or in the absence of local

codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.
Southbend reserves the right to change specifications and product design without notice. Such revisions do not entitle

the buyer to corresponding changes, additions, or replacements for previously purchased equipment.
This product is intended for commercial use only, not for household use.

ELECTRICITY SUPPLY

Supply

Voltage

Oven Component

Total

kW

3-Phase Loading (kW/phase)

Nominal Amperes per Line-

Wire

3-Phase

Minimum Supply

Wire (AWG) Size

L1-L2

L2-L3

L1-L3

L1

L2

L3

1-Phase

Total

1-Phase 1-Phase

480

Heating Elements

11.00

3.67

3.67

3.67

13.2

13.2

13.2

22.9

12

10

Motor & Controls

0.90

0.00

0.00

0.00

2.2

0.0

2.2

2.2

415

Heating Elements

11.00

3.67

3.67

3.67

15.3

15.3

15.3

45.9

12

6

Motor & Controls

0.90

0.00

L3-N

0.90

0.0

0.0

3.8

3.8

380

Heating Elements

11.00

3.67

3.67

3.67

16.7

16.7

16.7

28.9

12

8

Motor & Controls

0.90

0.00

L3-N

0.90

0.0

0.0

4.1

4.1

240

Heating Elements

11.00

3.67

3.67

3.67

26.4

26.4

26.4

45.8

8

6

Motor & Controls

0.90

0.00

0.00

0.90

3.8

0.0

3.8

3.8

220

Heating Elements

9.25

3.10

3.10

3.10

24.2

24.2

24.2

42.0

8

6

Motor & Controls

0.90

0.00

0.00

0.90

4.1

0.0

4.1

4.1

208

Heating Elements

11.00

3.67

3.67

3.67

30.5

30.5

30.5

52.9

8

4

Motor & Controls

0.90

0.00

0.00

0.90

4.3

0.0

4.3

4.3

An electrical diagram is located on the side of the control panel assembly (see drawing on page 35). Electrical

diagrams can also be found in this manual beginning on page 36.
The electrical connections are made directly to the terminals of the heating-element contactor, which is located

inside the control-panel compartment on the right side of the oven. A circular opening sized for a strain-relief

fitting is located on the back of the oven near the right side (right as seen from the front of the oven, see illus-

tration on page 16). Models with two stacked ovens have a separate electrical connection for each oven.
Use 167°F (75°C) wire for all supply lines.
Ovens are shipped wired for either single-phase or three-phase operation, depending on which was specified

on the factory order. If necessary, an oven can be field-converted to use either single-phase or three-phase

power (see page 32).

S

PECIFICATIONS

The following table lists the electricity supply requirements PER OVEN (double for dual-oven models).