E

LECTRIC

C

ONVECTION

O

VENS

OPERATOR’S MANUAL 1181958 REV 5 (4/14)

PAGE

7

OF47

WARNING

There must be adequate clearance between the left side of the ovens and combustible construction..

Minimum Clearance from

Combusble Construction

Minimum Clearance from

Non-Combustible Construction

Back

2”

2”

Right Side

0”

0”

Left Side

0”

0”

Floor

0”

0”

Adequate clearance must be provided in the aisle to allow the doors to open sufficiently to permit the removal of the

racks and for serviceability.
Although no clearance is required behind the motor on the rear of the oven, care must be taken to provide adequate

air circulation to prevent the motor from overheating.
Do not locate the oven adjacent to any high heat or grease-producing piece of equipment, such as a range top,

griddle, fryer, etc., that could allow radiant heat to raise the exterior temperature of the oven above 130°F (54°C).

DO NOT MOUNT ABOVE OTHER COOKING EQUIPMENT.

S

PECIFICATIONS

MINIMUM CLEARANCES

NOTICE

Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the

warranty.

If a ventilation canopy is used, it is recommended that a canopy extend 6” past the appliance and that the bottom edge be

located 6’6” from the floor. Filters should be installed at an angle of 45° or more from the horizontal. This position prevents

dripping grease and facilitates collecting the run-off grease in a drip pan, unusually installed with a filter.

If an exhaust fan is used, it should be installed at least 2” above the flue opening at the top of the unit. A strong exhaust

fan tends to create a vacuum in the room. Fresh air openings approximately equal to the fan area will relieve such a

vacuum. In case of unsatisfactory performance on any appliance, check the appliance with the exhaust fan in the “OFF”

position. Do this only long enough to check equipment performance. Then turn the exhaust fan back on and let it run to

remove any exhaust that may have accumulated during the test.