All wire and cable interfaced to the Xtramix and Speck products should
be terminated with high quality connectors. A 1/4" plug or XL
connector should make a positive connection to its respective mating
jack and provide adequate strain relief to its cable. All connectors
should also have a metal shell to provide 100% shield for exposed
conductors.

Feel free to check with Speck Electronics for assistance when selecting
cable and connectors. Our phone number is +760-723-4281.


When you are evaluating voltage and current requirements for your
audio system, it is important that your Xtramix mixing system and/or
rack system does not exceed the capacity of your AC service. You
should make certain that the earth (green) wire for the AC system makes
a reliable earth connection, and determine as best as possible that the AC
system is free of noise that could generate unwanted audible sounds or
cause problems in microprocessor based equipment.

When using a larger rack system it is recommended that a dedicated and
isolated AC service be provided. This service should have its own AC
wires, isolated receptacle, and breaker and not be shared with other
unrelated equipment.

Even with an isolated AC system, it may still be necessary to make use
of surge protectors, line filters, isolation transformers, or all of the
above.

Power conditioners should be selected with care, since they sometimes
generate undesirable switching noises in audio systems.

When connecting many pieces of electronic equipment to an AC system
it is important that the AC is properly distributed. It is better to connect
all plugs to a common AC source than to have AC receptacles in
different locations.

When installing a large audio system, it may be necessary to consult a
qualified electrician that is familiar with the specialized style of
electrical wiring required for recording studios.

Connectors

Quality AC System

AC Distribution

46

CAUTION!

DO NOT REMOVE, DEFEAT, OR DISABLE THE SAFETY

EARTH TERMINAL ON THE POWER CORD. DO NOT USE A

GROUND LIFT ON THE POWER SUPPLY.

Proper AC Grounding