Figure 8: receiving frame mounting holes – StorCase Technology DE300i-SWC160 User Manual

Page 18

Advertising
background image

DE300i-SWC160 User's Guide - Rev. B00

StorCase Technology, Inc.

Installation

11

Mounting
Holes
(Right)

0520

Mounting
Holes
(Bottom)

Front of Unit

Figure 8: Receiving Frame Mounting Holes

5.

Adjust the front of the receiving frame so the carrier slides freely in and out on

the receiving frame guides. The position of adjoining peripheral units may require

adjustment.

6.

To connect a drive to a Remote Activity LED in the computer system or expansion

chassis, connect the appropriate cable(s) to the receiving frame motherboard

as shown in Figure 5. Connect J3A, J3B, and J3C Pins 11 & 12 to a remote activity

LED.

7.

Connect the I/O cables from the host adapter to the receiving frame. The Pin 1

indicator on the cable must be properly aligned. Refer to Figure 5 for the correct

Pin 1 location.

NOTE:

No onboard termination is provided on the DE300i-SWC160.

External termination must be provided.

4.

With the drive carriers locked into place inside the receiving frame, install the

DE300i-SWC160 receiving frame into the drive opening in the computer or

expansion chassis. Use the appropriate guides to position the DE300i-SWC160,

and fasten it into place with the four (4) #6-32 x 1/4” screws provided. Figure

8 illustrates the location of the mounting holes. Mounting holes are provided on

each side and the bottom of the receiving frame to accommodate a variety of

mounting configurations. Use the mounting holes which best suit the computer

or expansion chassis configuration.