Saf-te board scsi id set-up – StorCase Technology S10A100 User Manual

Page 12

Advertising
background image

StorCase Technology, Inc.

SAFTEmon User’s Guide - Rev. E00

12

S10A100

SAF-TE Board SCSI ID Set-Up

(The following information only applies to the 9 & 14-Bay 4U InfoStations)

NOTES:

SAF-TE board SCSI ID is factory set to SCSI ID15.

The SAF-TE SCSI ID can be changed anytime. It will only take effect after a

system power up however.

Press CANCEL at anytime to exit the menu system and return to the Default

Display. The menu system will automatically cancel after 15 seconds of User

inactivity.

The following steps show how to change the SAF-TE board SCSI ID via the InfoStation UI

Module. Refer to the InfoStation User's Guide (specifically, section "InfoStation User

Interface") for further information.

1.

Press ENTER at the Default Display so that

display = Status.

2.

Press DOWN until display = SAFT Cfg.

3.

Press ENTER so that display = SCSI ID.

4.

Press ENTER again so that display = SAFT1:xx.

This is the current SAF-TE SCSI ID.

5.

Press UP or DOWN to change the SAF-TE SCSI

ID.

6.

Press ENTER to accept the change.

Advertising