User manual – SurgeX Defender Series Surge + Diagnostic User Manual

Page 12

Advertising
background image

User Manual




© 2013 SurgeX / Electronic Systems Protection, Inc. /

Technical Support 800.645.9721 /

www.surgex.com /

11

3.2

Clearing Memory

The Surge + Diagnostic

is able to timestamp the 60 most recent power quality events (information stored

in microcontroller non-volatile memory). The microcontroller memory contents can be cleared at any time

by following one of these two methods:

3.2.1 RST Button

There is a recessed push button located on the front panel.



a.

Follow these steps to clear the device memory:

1. Unplug the input cord of the Surge + Diagnostic from the branch circuit outlet.
2. Using a paperclip or small screwdriver, press and hold the RST button.

3. Plug the input cord of the Surge + Diagnostic into a properly grounded and

compatible branch circuit outlet, while continuing to hold the RST button.

4.

Wait approximately 3-5 seconds; the LCD Event Monitor will now display “cLr”; release
the RST button and the device microcontroller memory will now be cleared

.


3.2.2

Diagnostic Software

The device microcontroller memory may alternately be cleared from within the Diagnostic

Software in the following location: “Tools/Clear Device Memory”. See Section 4– 4.3- C: Tools
Menu, for details

.







Advertising