2. For the Master and Slave, ensure the Azimuth (AZ) and

Elevation (EL) Adjustment Bolts are in the middle of their

adjustment ranges.

Elevation (EL)

Adjustment Bolt

Azimuth (AZ)

Adjustment Bolt

3.

Master

Aim the Master at the Slave. If necessary, adjust the

Master's position on the pole:

a. Loosen the Hex Nuts.
b. Adjust the Pole Mount Bracket and Pole Clamps.
c. Tighten the Hex Nuts.

Hex Nuts

4.

Slave

Aim the Slave at the Master to achieve the strongest

received signal level on the Slave's numeric LED Display, which
is located next to the CONFIG port. If necessary, adjust the
Slave's position on the pole.

Slave RF Power (-dBm)

Note:

Values on the LED Display are displayed in

negative (-) dBm. For example, 61 represents -61 dBm,

which is stronger than -72 dBm.