3) sync-switch – Vermona fourMulator - quad modulation engine User Manual

Page 11

Advertising
background image

For modulators being synchronized and being shifted in phase, the LED
flash with the same tempo but with a corresponding delay.

(3) SYNC-switch

The SYNC switch offers three positions: OFF, SYNC and CLK (Clock).

NOTE

Modulator 1 only offers OFF and CLK positi-
ons since it can only be used as a sync refe-
rence but cannot be synchronized itself.

OFF

The modulator runs at the speed set with the corresponding SPEED
control.

SYNC (indicated by the numbers , and )

The modulator is synchronized to its left counterpart. It follows the
clock-reference's speed. By this, multiple modulators can be varied in
frequency at once using the SPEED control of the modulator acting as
clock-reference. In sync-mode, SPEED controls the phase of the syn-
chronized modulator (see "(2) SPEED- and SPEED/PHASE controls",
page 10).

NOTE

It is possible, to synchronize two or even three
modulators with modulator 1 by setting the
adjacent sections to sync. Also, modulators 1
and 2 as well as modulators 3 and 4 can be
used as independent synced pairs.

CLK

The modulator is either synchronized to an internal or external clock
signal (see chapter 2.3). Use SPEED- or SPEED/PHASE to select one of
eight available clock division settings, i.e. the modulators' speed will
only move within a clock related grid.

Neither the internal clock nor an external signal is predefined. A
clock can work with any resolution, e.g. with 4, 16 or 96 impulses per

Owner's Manual VERMONA Retroverb Lancet

- 11 -

Advertising