ENVISION CONSOLE - 50 HZ INSTALLATION MANUAL

Electrical Data

Blower Performance Data

Model

Rated

Voltage

Voltage

Min/Max

Compressor

Blower

Motor

FLA

Total

Unit
FLA

Min

Circ

Amp

Max

Fuse/
HACR

MCC

RLA

LRA

02

220-240/50/1

198/264

6.4

4.1

17.0

2.6

6.7

7.7

10/15

03

220-240/50/1

198/264

7.6

4.9

18.7

2.6

7.5

8.8

10/15

04

220-240/50/1

198/264

9.2

5.9

23.0

2.6

8.5

10.0

15

05

220-240/50/1

198/264

10.5

6.7

24.0

2.6

9.3

11.0

15

HACR circuit breaker in USA only

3/05/14

ECM Blowers

PSC Blowers

Model

Rated

Voltage

Voltage

Min/Max

Compressor

Blower

Motor

FLA

Total

Unit
FLA

Min

Circ

Amp

Max

Fuse/
HACR

MCC

RLA

LRA

02

220-240/50/1

198/264

6.4

4.1

17.0

0.50

4.6

5.6

10/15

03

220-240/50/1

198/264

7.6

4.9

18.7

0.50

5.4

6.6

10/15

04

220-240/50/1

198/264

9.2

5.9

23.0

0.69

6.6

8.1

10/15

05

220-240/50/1

198/264

10.5

6.7

24.0

0.69

7.4

9.1

15

HACR circuit breaker in USA only

3/05/14

Model

LPS

Low Speed

High Speed

02

120

140

03

120

140

04

175

200

05

175

200

Factory settings are in Bold
Air fl ow values are with dry coil and standard fi lter.

For wet coil performance fi rst calculate the face velocity of the air
coil (Face Velocity [mps] = Airfl ow [lps] / Face Area [m

2

]). Then for

velocities of 1 mps, reduce the static capability by 7.5 pa, 1.5 mps by 19.9
pa, 2 mps by 29.9 pa and 2.5 mps by 39.8 pa.

PSC Blowers

ECM Blowers

Model

LPS

Low Speed

Medium Speed

High Speed

02

140

150

190

03

140

150

190

04

165

210

280

05

165

210

280

Factory settings are in Bold
Air fl ow values are with dry coil and standard fi lter.

For wet coil performance fi rst calculate the face velocity of the air
coil (Face Velocity [mps] = Airfl ow [lps] / Face Area [m

2

]). Then for

velocities of 1 mps, reduce the static capability by 7.5 pa, 1.5 mps by 19.9
pa, 2 mps by 29.9 pa and 2.5 mps by 39.8 pa.