5

asterisk will appear by that channel name and the middle knob (as prompted by the display) then
controls the level offset for that channel.

Press any of the other mode select buttons to exit from volume mode.

Bypassing Filter Bands

+00.0

+00.0

0.4

1K00

3K15

0.4

1K00

0.4

1K00

lo

1K00

hi

+00.0

byp

left/right front

+00.0 +00.0

1K00

0.4

Figure 5 - band bypass mode

It is simple to audition the effect of a single band of equalization on the z-Q6. The band select
button

can also be used to bypass the active band of EQ. Simply press the band select button

under the desired EQ band. As shown in Figure 5, the display will then show the word "byp" in
that band's gain display and the band will be bypassed. Press the band select button again to
return from bypass.

Important note: None of the z-Q6's controls will work until you return the band from
bypass.

Bypassing the Entire EQ

bypass

Figure 6 - master bypass mode

Press the master bypass button to bypass the entire z-Q6. The display will appear as in Figure 6.
In the bypass mode the input and output of the z-Q6 will be identical on all six channels. To
return from bypass mode, press the master bypass button again. The master bypass button only
functions from volume control and EQ modes.