Parameter

Value

Description

I/O Data Flow

Streaming

Variable Streaming

Buffered Burst

Burst

If you select Variable Streaming and Floating

Point, the precision is automatically set to 32, and

the reverse I/O order options are Digit Reverse

Order.

I/O Order

Bit Reverse Order,

Digit Reverse Order,

Natural Order, N/2

to N/2

The input and output order for data entering and

leaving the FFT (variable streaming FFT only).

The Digit Reverse Order option replaces the Bit

Reverse Order in variable streaming floating

point variations.

Data Representation

Fixed point or single

floating point, or

block floating point

The internal data representation type (variable

streaming FFT only), either fixed point with

natural bit-growth or single precision floating

point. Floating-point bidirectional IP cores expect

input in natural order for forward transforms and

digit reverse order for reverse transforms. The

output order is digit reverse order for forward

transforms and natural order for reverse

transforms.

Data Width

8, 10, 12, 14, 16, 18,

20, 24, 28, 32

The data precision. The values 28 and 32 are

available for variable streaming only.

Twiddle Width

8, 10, 12, 14, 16, 18,

20, 24, 28, 32

The twiddle precision. The values 28 and 32 are

available for variable streaming only. Twiddle

factor precision must be less than or equal to data

precision.

The FFT IP core's advanced parameters.

Table 3-5: Advanced Parameters

Parameter

Value

Description

FFT Engine Architec‐

ture

Quad Output, Single

Output

Choose between one, two, and four quad-output

FFT engines working in parallel. Alternatively, if

you have selected a single-output FFT engine

architecture, you may choose to implement one

or two engines in parallel. Multiple parallel

engines reduce transform time at the expense of

device resources, which allows you to select the

desired area and throughput trade-off point.
Not available for variable streaming or streaming

FFTs.

Number of Parallel

FFT Engines

1, 2, 4

UG-FFT

2014.12.15

FFT IP Core Parameters

3-15

FFT IP Core Functional Description

Altera Corporation

Send Feedback