Chapter 3: Functional Description

3–3

Design Example: Series Calibration for Four Calibration Blocks Using Stratix III Device

February 2012

Altera Corporation

Dynamic Calibrated On-Chip Termination (ALTOCT) Megafunction

User Guide

Use a QSF assignment to indicate which pin (bus) is associated with which
calibration block.

f

For more information about the OCT architecture and the calibration modes for other
device families, refer to the respective device handbooks.

Design Example: Series Calibration for Four Calibration Blocks Using
Stratix III Device

This design example uses the ALTOCT megafunction to calibrate four calibration
blocks using series termination for the Stratix III device. This example uses the
MegaWizard Plug-In Manager in the Quartus II software.

In this example, you perform the following tasks:

Generate the dynamic on-chip termination calibration blocks using the ALTOCT
megafunction in the MegaWizard Plug-In Manager

Ensure that correct termination assignments are used in the design by using the
Assignment Editor

Simulate the design in the ModelSim-Altera software

The design examples are available for download from the following locations:

On the

Documentation: Quartus II Development Software

page, expand the Using

Megafunctions

section and then expand the I/O section.

On the

Documentation: User Guides

section of the Altera website.

Generate the Dynamic On-Chip Termination Calibration Blocks

Perform the following steps to generate the dynamic on-chip termination calibration
blocks:

1. Open altoct_DesignExample.zip and extract altoct_ex.qar.

2. In the Quartus II software, open altoct_ex.qar and restore the archive file into your

working directory.

3. Open the top-level file, altoct_ex.bdf.

4. Double-click on a blank area in the schematic.

5. In the Symbol window, click MegaWizard Plug-In Manager. Page 1 of the

MegaWizard Plug-In Manager appears.

6. Select Create a new custom megafunction variation.

7. Click Next. Page 2a of the MegaWizard Plug-In Manager appears.