Connecting the power supply, 14 stm23 hardware manual – Applied Motion STM23C-3CE User Manual

Page 14

Advertising
background image

To Power Supply +

To Earth Ground

To Power Supply –

Connecting the Power Supply

If you need information about choosing a power supply, please read “Choosing a Power Supply” located above in

this manual.

Connect the motor power supply “+” terminal to the driver terminal labeled “+”. Connect power supply “-” to the

drive terminal labeled “-”. Use wire in the range of 16 to 20 AWG. The STM23 drives contain an internal fuse that

connects to the power supply + terminal. This fuse is not user replaceable. If you want to install a user serviceable

fuse in your system install a 4 amp fast acting fuse in line with the + power supply lead.

It is important that the motor frame be electrically connected to ground. When the motor is mounted on an insu-

lated surface, a ground wire is required as shown in the diagram below. Also, in applications where multiple STMs

are used on a machine, individual ground wires may reduce the overall electrical noise level.

Be careful not to reverse the wires. Reverse connection may open the internal fuse on your driver and

void your warranty.