Led error codes, 47 stm23 hardware manual – Applied Motion STM23C-3CE User Manual

Page 47

Advertising
background image

LED Error Codes

Status LED STM

The STM drive+motor includes red and green LEDs to indicate status. When the motor is enabled, the green LED

flashes slowly. When the green LED is solid, the motor is disabled. Conditions and errors are indicated by combina-

tions of red and green “flashes” as follows:

Code

Condition

solid green

no alarm, motor disabled

flashing green(slow)

no alarm, motor enabled

1 red, 1 green

motor stall (optional encoder only)*

1 red, 2 green

move attempted while drive disabled

2 red, 1 green

ccw limit

2 red, 2 green

cw limit

3 red, 1 green

drive overheating*

3 red, 2 green

internal voltage out of range*

4 red, 1 green

power supply overvoltage*

4 red, 2 green

power supply undervoltage

5 red, 1 green

over current / short circuit*

6 red, 1 green

open motor winding*

7 red, 1 green

serial communication error

flashing green(fast)

Q Program running

*These errors are faults and will disable the motor. They also cause the output to activate if it is so configured.

47

STM23 Hardware Manual

920-0021F

2/14/2012

Advertising
This manual is related to the following products: