Command

Feedback

Description

IPCFG

IP Addr : x.x.x.x
Netmask : x.x.x.x
Gateway : x.x.x.x
IP Port: x.x.x

Displays IP address configuration

IPTimeout XX

IPTimeout XX
(Ex. IPTimout120)

Determines amount of seconds of inactivity before TCP/IP
disconnects

IPQuit

IPQuit

Logs out of TCP/IP

IPAddUser

TCP/IP username & password list:
- user password
- user password
- user password

Will display a list of users

IPAddUser [X] [Y]

TCP/IP user was added

Add a user for TCP/IP control. X=User Y=Password
Ex. IPAddUser Atlona 1234 (User=Atlona 1234=Password)

Each command or feedback is terminated with a carriage return.

Note: If the command fails or is incorrect the feedback should be “Command FAILED”

TCP/IP Commands

RS-232 & TCP/IP Control Commands

The command codes are case sensitive, do not change capitalization, spacing, or lettering.

Command

Feedback

Description

PWON

PWON

Power on

PWOFF

PWOFF

Power off

PWSTA

PWx

Will display the power status of the matrix (ex. Power is on = PWON)

Version

(Firmware #)

Brings up the current firmware version

Type

(Model #)

Brings up the model information

Lock

Lock

Locks the front panel of the matrix so no buttons are active

Unlock

Unlock

Unlocks the front panel of the matrix, enabling the buttons again

All#

x1AVx1,x2AVx2,...

Resets all inputs to corresponding outputs (in3 to out3)

x1$

x1$

Turns off output channel (to turn off output 3 = x3$)

x1All

x1All

Sets selected input to all outputs
(x3All would set input 3 to all)

x1AVx2

x1AVx2

Switch input to output (input 3 to output 2 = x3AVx2)

x1AVx2,x3,x4

x1AVx2,x3,x4

Switch input to multiple outputs (input 3 = x3AVx1,x2)

IRON

IRON

Turns on the IR receiver

IROFF

IROFF

Turns off the IR receiver

Statusx1

x7AVx1

Shows what input is connected to selected output

Status

x1AVx1,x2AVx2,
x3AVx4, ....

Displays which inputs are currently connected to which outputs

SaveY (ex. Save2)

SaveY (ex. Save2)

Saves settings for future use, preset options 0 to 4

RecallY (ex. Recall2)

RecallY (ex. Recall2)

Recalls saved settings for the number you selected

ClearY (ex. Clear2)

ClearY (ex. Clear2)

Erases the save for the number you selected

Mreset

Mreset

Sets matrix back to the default settings