CEL-269 Digital Integrating Sound Level Meter

Instructions

The CEL-269 Digital Integrating Impulse Sound

Level Meter has been designed to meet the

measurement requirements of Safety Engineers,

Occupational Nurses, Industrial Safety Officers,

and other specialists who require inexpensive and

easily used instrumentation to determine whether

industrial noise exposure areas require a more

detailed investigation.

The instrument features an eight-bit micro-

processor that calculates the time averaged levels

continuously. L

eq

(the equivalent continuous noise

level) represents the steady continuous level

which would have the same energy content as

the varying noise level being measured. It is

obtained by integrating sound pressure levels

with respect to time according to:

L

AG

=

10log 1

T

0

T

(

P

P

0

)

2

dt

Where P is the instantaneous sound pressure, P

0

the reference pressure 2 x 10

-5

Pa, and T the

measurement duration.

The microprocessor also calculates the time

constants required for measuring with the

standard time weightings: Fast, Slow, and

Impulse (with reset function), and there is a

maximum hold mode that operates with all time

constants.

The instrument satisfies the requirements of IEC

651 Type 2, BS 5969 Type 2, and ANSI S1.4 Type

2A standards for both free field and random

incidence sound level meters, IEC 651 Type 2I for

impulse sound level meters, and IEC 804, BS

6698 for integrating sound level meters.

A clear and unambiguous digital indication of the

A-weighted and C-weighted sound levels is

provided by the custom made display, that

includes an indication of overload and under range

conditions, and may be switched to show battery

voltage.

The instrument can measure sound levels

between 30 dB(A) and 135 dB(A) in two ranges,

at frequencies between 10 Hz and 20 kHz. An

output signal is available from a single standard

3.5 mm 3-pole coaxial socket, so that it may be

used with graphic level and tape recording

systems.

INTRODUCTION

A complete "CEL-269 Digital Integrating Impulse

Sound Level Meter" consists of the following

items.

CEL-269

Sound Level Meter,

32460

Microphone Cover,

16022

Type AAA Manganese

Alkaline Battery (4 off),

38055

Screwdriver,

60114

Instructions.

The following accessories may be ordered

separately to enable the user to gain the

maximum advantage from the instrument.

CEL-4672/2 Windshield,

CEL-5894 Case for measuring kit,

CEL-284/2 Acoustical Calibrator Class 1

(complete with CEL-4725

Microphone Coupler),

CEL-282

Acoustical Calibrator Class 2

(complete with CEL-4725

Microphone Coupler),

C4963/2

Tape Recorder Cable (2 m) with

3.5 mm jack plug & BNC plug for a.c

output.

Install four type AAA Manganese Alkaline

batteries and the instrument is ready for use. Zinc

carbon batteries are NOT suitable.

The two battery compartments are exposed

when the coloured cover is removed as shown.

One compartment in the front of the instrument

inner case houses two batteries, with an identical

compartment at the back.

Observe the battery polarities indicated in the

figure and in each compartment, and replace

batteries when

is indicated on the display.

Having inserted a set of batteries, replace the

coloured cover and ensure that it is firmly held by

the retaining clips. The actual battery voltage can

be determined by sliding the RESPONSE switch

to F, then pressing the MODE button repeatedly

to cycle the display function until the voltage is

displayed.

The instrument is now ready for service.

PREPARATION FOR USE

Advertising