--------- MULTIMETER CURRENT CLAMP

CPM

-------- PG No. 5

-

DC Voltage

Range

Accuracy

Input impedance

Overload protection


600 V
± (0.5% read. + 1 digit)
10 M

600 V DC or AC rms

AC Voltage (50-500 Hz)

Ranges

Accuracy

Input impedance

Overload protection


200 V, 600 V
± (1.2% read. + 4 digits)
10 M

600 V DC or AC rms

Resistance

Ranges

Accuracy

Open circuit voltage

Overload protection


2 k

, 200 k

± (1.2% read. + 1 digit)
0.3 V DC
600 V DC or AC rms

Frequency (Autoranging)

Ranges

Accuracy

Sensitivity

Overload protection


2 kHz, 20 kHz
± 0.1% read. + 3 digits.
80 V rms minimum
600 V DC or AC rms