INTRODUCTION


The purpose of this manual is to assist during the installation, start-up and maintenance of low
voltage (LV) capacitor banks switched by contactors. Carefully read the manual to achieve the
best equipment performance.

2

SAFETY HAZARDS AND WARNINGS

2.1

Hazards encountered during the installation and start-up of electrical equipment.

The installation, operation and maintenance of low voltage (LV) equipment must

only be carried out by authorised installers. LV regulations (Art. 22) specifically
define the requirements that authorised installers must meet.

Do not access the active parts of a capacitor bank that has power supply applied

until a minimum of 5 minutes has elapsed from the time the power was
disconnected.

Do not touch the terminals or active parts of the unit until you have verified that

voltage is not present. If you must handle or touch the terminals or other
components of the control panel, use adequately insulated personal protection
equipment and tools.

After maintenance and before re-applying power to the unit, check that its enclosure

is properly closed and that no items or tools were left inside that could cause a
short-circuit.

Do not disconnect the current transformer secondary without short-circuiting it first.

The operation of a current transformer with an open secondary will cause an
overvoltage that can damage it and electrocute the person that is handling it.

2.2

Safety warnings

Apart from the general standards listed above, the standards and applicable laws of

the country where the capacitor bank is installed or operated should be strictly
followed.

Installation or maintenance personnel should read and understand this manual

before operating the equipment.

A copy of this manual should always be available to maintenance personnel for

reference.

Connecting the equipment to the public grid will be carried out in compliance with

standard EN-IEC60204-1, regarding the safety of LV electrical installations.

It is recommended that several personnel be present when manipulating the

equipment for its installation or maintenance.

If damage or faults are detected during equipment operation, or in circumstances

that may compromise safety, immediately stop work in that area and
disconnect the equipment in order to check it while it is de-energized.

Modifying, upgrading, or rebuilding the equipment without written authorization from

the manufacturer is prohibited.