Bi-directional Serial RS-232/422/485

Overview

These bi-directional serial channels are used for RS-232, RS-422 and RS-485 communication.
Baud rate can be set to the following values: 300, 600, 1 200, 2 400, 4 800, 9 600, 19 200, 38 400, 57 600,

115 200, 230 400 and 460 800 Bd (bps).
Default mode for all channels is RS-232, other modes must be set in programming application. For more

details see programming manuals.

RS-232 Mode

Output signal levels for RS-232 are in the -10 V to +10 V range. This is default mode for all channels.
Connector pin out

SERIAL RS-232

5-pin 3.5 mm

Pin

Signal

Description

Direction

1 2 3 4 5

1

TxD

RS-232 Transmitted Data

From interface

2

RTS

RS-232 Request to Send

From interface

3

GND

Ground

4

RxD

RS-232 Received Data

To interface

5

CTS

RS-232 Clear to Send

To interface

RS-422 Mode

This mode must be set in the programming application.
Connector pin out

SERIAL RS-422

5-pin 3.5 mm

Pin

Signal

Description

Direction

1 2 3 4 5

1

Tx A+

RS-422 Transmit Data (Idles High)

From interface

2

Tx B-

RS-422 Transmit Data (Idles Low)

From interface

3

GND

Ground

4

Rx A+

RS-422 Receive Data (Idles High)

To interface

5

Rx B-

RS-422 Receive Data (Idles Low)

To interface

RS-485 Mode

This mode must be set in the programming application.
Connector pin out

SERIAL RS-485

5-pin 3.5 mm

Pin

Signal

Description

1 2 3 4 5

1

A+

RS-422 Transmit Data (Idles High)

2

B-

RS-422 Transmit Data (Idles Low)

3

GND

Ground

4

N.C.

RS-422 Receive Data (Idles High)

5

N.C.

RS-422 Receive Data (Idles Low)

Advertising