smartCUE Interfaces | User Manual | Control Ports

© CUE, a.s. All Rights Reserved. | www.cuesystem.com | [email protected]

IR/SERIAL

This type of port provides

▪ Output for infra-red emitters (IR Adapter /i, IR Sprayer)

▪ RS-232 serial output (one way). Output signal levels are in the -12 V to +12 V range and baud rate can

be set to the following values: 1 200, 2 400, 4 800, 9 600, 19 200, 38 400, 57 600, 115 200 Bd (bps).

The IR outputs and RS-232 outputs can be combined on independent outputs. For example two outputs can

be used as IR, two outputs can be used as RS-232.
Connector pin out

IR/SERIAL

2-pin 3.5 mm

Pin

Signal

Description

S G

S

Signal

IR/Serial Signal (Output)

G

GND

Ground

Notes

▪ All pins labelled G are connected together.

▪ Up to three original infra-red emitters IR Adapter /i can be connected to each output in parallel.

▪ Up to ten IR Sprayers can be connected to each output in parallel

▪ It is not recommended to connect more infra-red emitters of various manufacturers in parallel because

the output can be either overloaded or damaged.