Addressing – CUE inputCUE-W User Manual

Page 9

Advertising
background image

4. Addressing

The ADDRESS of the inputCUE-W can be set in the range 0 to 207. Default ADDRESS is 1.

The BUTTON_ID transmitted by the inputCUE-W is the LINK number used in the programming for
button identification. The BUTTON_LED_ID is LED identification for ButtonLed… commands. Both
values depend on the Input (Output) Number and on the ADDRESS too. BUTTON_ID is calculated
according to the formulas described below.

BUTTON_ ID

=

(32 * ADDRESS) + Input Number

BUTTON_LED_ID

=

(32 * ADDRESS) + Output Number

The ADDRESS of the inputCUE-W is binary coded by DIP switch.

Switch view

Switch nr.

Function

SW1

ADDRESS bit 0

SW2

ADDRESS bit 1

SW3

ADDRESS bit 2

SW4

ADDRESS bit 3

SW5

ADDRESS bit 4

SW6

ADDRESS bit 5

SW7

ADDRESS bit 6

SW8

ADDRESS bit 7

ADDRESS

SW1

SW2

SW3

SW4

SW5

SW6

SW7

SW8

0

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

3

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

...

207

ON

ON

ON

ON

OFF

OFF

ON

ON

In the table below Button ID range for some addresses is shown.

ADDRESS

BUTTON_ID range = BUTTON_LED_ID range

0

1

8

1

33

40

2

65

72

207

6625

6632

User Manual inputCUE-W

www.cuesystem.com

Page 9 of 14