Addressing – CUE inputCUE User Manual

Page 7

Advertising
background image

User Manual inputCUE

www.cuesystem.com

Page 7 of 14

4. Addressing

The BUTTON_ID transmitted by the inputCUE is calculated according formula below.

BUTTON_ID = Offset + Input #

Offset

= 8 * ADDRESS


The lowest BUTTON_ID is generated by the input marked 1 the highest BUTTON_ID is generated by
the input marked 8.

The ADDRESS of the inputCUE is binary coded by DIP switch. The range is 0 to 255.

Switch view

Switch nr.

Function

SW1

ADDRESS bit 0

SW2

ADDRESS bit 1

SW3

ADDRESS bit 2

SW4

ADDRESS bit 3

SW5

ADDRESS bit 4

SW6

ADDRESS bit 5

SW7

ADDRESS bit 6

ON

1

7

6

5

4

3

2

8

SW8

ADDRESS bit 7

ADDRESS

SW1

SW2

SW3

SW4

SW5

SW6

SW7

SW8

0

OFF OFF OFF OFF OFF OFF OFF OFF

1

ON OFF OFF OFF OFF OFF OFF OFF

2

OFF ON OFF OFF OFF OFF OFF OFF

3

ON ON OFF OFF OFF OFF OFF OFF

4

OFF OFF ON OFF OFF OFF OFF OFF

5

ON OFF ON OFF OFF OFF OFF OFF

6

OFF ON ON OFF OFF OFF OFF OFF

7

ON ON ON OFF OFF OFF OFF OFF

8

OFF OFF OFF ON OFF OFF OFF OFF

9

ON OFF OFF ON OFF OFF OFF OFF

...

255

ON ON ON ON ON ON ON ON


In the table below there is Input ID range for each address.

ADDRESS

BUTTON_ID range

0 1 8

1 9 16

2 17 24

3 25 32

4 33 40

...

255 2041 2048