ILUMINARC Ilumipod™ 42 IP User Manual

Page 5

Advertising
background image

Ilumipod 42 IP Optic Series QRG

12

TOUR (Cont.)

Channel Function

Value

Percent/Setting

8

(Cont)

Programs (Cont.)

121  130
131  140
141  150
151  160
161  170
171  180
181  190
191  200
201  210
211  220
221  255

Custom 1
Custom 2
Custom 3
Custom 4
Custom 5
Custom 6
Custom 7
Custom 8
Custom 9
Custom 10
No Function

9

Auto Speed Adjust

000  255 0~100% (only when running auto programs)

10 Dimmer

Speed

000  009
010  029
030  069
070  129
130  189
190  255

Preset dimmer speed

Linear dimmer
Dimming curve 1 (fastest)
Dimming curve 2
Dimming curve 3
Dimming curve 4 (slowest)

Value

Setting

Value

Setting

Value

Setting

11

ID Addressing

000  009
010  019
020  029
030  039
040  049
050  059
060  069
070  079
080  089
090  099
100  109
110  119
120  129
130  139
140  149
150  159
160  169
170  179
180  189
190  199
200  209

210
211

All IDs
ID 1
ID 2
ID 3
ID 4
ID 5
ID 6
ID 7
ID 8
ID 9
ID 10
ID 11
ID 12
ID 13
ID 14
ID 15
ID 16
ID 17
ID 18
ID 19
ID 20
ID 21
ID 22

212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234

ID 23
ID 24
ID 25
ID 26
ID 27
ID 28
ID 29
ID 30
ID 31
ID 32
ID 33
ID 34
ID 35
ID 36
ID 37
ID 38
ID 39
ID 40
ID 41
ID 42
ID 43
ID 44
ID 45

235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255

ID 46
ID 47
ID 48
ID 49
ID 50
ID 51
ID 52
ID 53
ID 54
ID 55
ID 56
ID 57
ID 58
ID 59
ID 60
ID 61
ID 62
ID 63
ID 64
ID 65
ID 66


Ilumipod 42 IP Optic Series QRG

5

AC Power

This product has an auto-ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.

Power Linking

This product does not support power linking.

AC Plug

The IP66 power input cable in this product comes bare ended. Use the table
below to wire a plug for this product or see the connection diagram.

IP66 Power Cable

Table

Connection

Wire (US)

Wire (Europe)

IP66 Pin

AC Live

Black

Brown

1

AC Neutral

White

Blue

2

AC Ground

Green/Yellow

Green/Yellow

3

IP66 Connector

Pin out










Power Wiring

You can connect the bare-ended IP67 rated AC power cable from the fixture
to an IP66 rated power connector (Power Input and Power Output).

Alternatively, you may use IP66 rated junction boxes for surface
installations, or IP67 rated junction boxes for buried installations.

If using connection boxes, make sure to use IP66 rated conduit for surface
installations or IP67 rated conduit for buried installations. You could also
use direct buried cable (DBC) to link the junction boxes.

AC Power Junction

Box Wiring












F

emale Power IP66 Connector

(toward power line)

Male Power IP66 Connector

(toward fixture)

Advertising