Installation and operation, Wiring diagrams – Pinnacle Systems NSD User Manual

Page 12

Advertising
background image

7

Installation and Operation

NSD Safety Mat System

7.0"

6.25"

5.0"

4.25"

4 mounting holes (#8

screws)

120vac

power

Earth

Ground

Mat #1

Mat #2

2 Independent

Safety Outputs

A & B:

Wire each in

series with each

STOP circuit in

a DUAL STOP

system.

NOTE:

These are N.O.

Held Closed

outputs

Replacement

Safety Relay

32-101

NC-C-NO

Aux Output:

for status only

Replacement

relay 32-001

Push “Clear” button to Reset

mat control.

Mat Control will Auto-Reset

is both N.C. contacts are

disconnected.

GRN

RED

External Status

Indicators

24vdc

Indicators on

door are LED’s

with internal

resistors set for

24vdc

Connect either of the 2 wire pairs

to Terminal#1 & #2, and the other

pair to Terminal#3 & #4 (as

shown)

NSD Mat Wiring:

Style “X” or “E”

1 Black, 2 Red, 3 Black, 4 Red

Or Style “W” or “P”

1 Blue, 2 White, 3 Black, 4 Brown

White Steel

mounting plate

is used to

support the PCB

Power ON

A

B

Wiring Diagrams

NSD-TR-01 (Metal Box Controller)

NOTE: If you daisy chain mats, the blue/white is one
pair and should go to Terminals #1 and #2. The black/
brown is the other and should go to the blue/white pair
of the second mat, and so on. The black/brown pair of
the last mat goes back to Terminals #3 and #4.

If the mat has two lamp cords, then either pair can go
to Terminals #1 and #2 and so on.

Relay Fault LED’s D14,D18

(ON=good, OFF=Relay stuck on FAULT)

On Mat LED’s D10,D12

(ON=ON mat, OFF=OFF mat)

NOTE: Canadian market wiring is black, red, red,
black with 18-guage wiring size.