Status display / error codes – ZENNER zelsius C5 CMF User Manual

Page 9

Advertising
background image

9

Status display / Error codes

The symbols in the table below show the meter’s operational status. The status messages only appear in
the main display (energy)! The temporary display of the warning triangle can be caused by special operat-
ing states and does not always mean that the device is malfunctioning. However, should the symbol be
displayed over a longer period of time, you should contact the service company.

Error codes show faults detected by zelsius

®

C5-ISF. If more than one error appears, the sum of the

error codes is displayed: Error 1005 = error 1000 and error 5.

Code

Error

Event

1

Temperature out of measuring range

Check sensors

2

Temperature out of measuring range

Check sensors

3

Short-circuit return sensor

Check sensors

4

Interruption return sensor

Check sensors

5

Short-circuit supply sensor

Check sensors

6

Interruption supply sensor

Check sensors

7

Battery voltage

Exchange device

8

Hardware error

Exchange device

9

Hardware error

Exchange device

100

Hardware error

Exchange device

800

Wireless interface

Exchange device

1000

Status end of the battery

Exchange device respectively battery*

2000

Status Initial verification expired

Exchange device

* Due to certification reasons, change of the battery only possible abroad.

Symbol Status

Event

External voltage

-

Flow existent

-

Attention!

Check system / device for errors

Symbol flashing: Data transmission

-

Symbol constantly displayed: optical interface active

-

Emergency operation

Exchange device