2 byte-oriented synchronous receive, Byte-oriented synchronous receive – Zilog Z16C35 User Manual

Page 65

Advertising
background image

ISCC

User Manual

UM011002-0808

59

At this point, the other registers should be initialized as necessary. When all of this is com-
pleted the transmitter maybe enabled by setting bit 3 of WR5 to one. Now that the trans-
mitter is enabled the CRC generator maybe initialized by issuing the Reset Tx CRC
Generator command in WR0, bit 6-7.

4.3.2 Byte-Oriented Synchronous Receive

The CPU places the receiver in Hunt mode whenever transmission begins (or whenever a
data dropout has occurred and the hardware determines that resynchronization is neces-
sary). In Hunt mode, the receiver shifts a bit into the Receive Shift register and compares
the contents of the Receive Shift register and with the sync character (stored in another
register), repeating the process until a match occurs. When a match occurs, the receiver
begins transferring bytes to the receive FIFO.

Once the sync character-oriented mode has been selected, any of the four sync character
length maybe selected: 6-bits, 8-bits, 12-bits, or 16-bits.

The Table 4-7 shows the WR register bit setting for selecting sync character length.

Table 4-7. Sync Character Length Selection

The arrangement of the sync character in WR6 and WR7 is shown in Figure 4-5.

5,6

select number of bits
per character

WR10

7

CRC preset value

Table 4–15. Sync Character Length Selection

Sync Length

WR4,D5

WR4,D4

WR10,D0

6 bits

0

0

1

8 bits

0

0

0

12 bits

0

1

1

16 bits

0

1

0

Table 4–14. Transmitter Initialization in Character Oriented Mode