Instruction Description

192

Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the
source or destination Working Register operand is specified by adding

1110b

(

Eh

) to the

high nibble of the operand. For example, if Working Register R12 (CH) is the destination
operand, then

ECh

is used as the destination operand in the Op Code.

Example 1

The statement:

LD R15, #34h

Op Code: FC 34

loads the value

34h

into Working Register R15.

Example 2

If Register

34h

contains the value

FCh

, the statement:

LD R14, 34h

Op Code: F8 34

loads the value

FCh

into Working Register R15. The contents of Register

34h

are not

affected.

Example 3

If Working Register R14 contains the value

45h

, the statement:

LD 34h, R14

Op Code: E9 34

loads the value

45h

into Register

34h

. The contents of Working Register R14 are not

affected.

Example 4

If Working Register R12 contains the value

34h

, and Register

34h

contains the value

FFh

,

the statement:

LD R13, @R12

Op Code: E3 DC

loads the value

FFh

into Working Register R13. The contents of Working Register R12

and Register R34 are not affected.

Example 5

If Working Register R13 contains the value

45h

, and Working Register R12 contains the

value

00h

the statement:

LD @R13, R12

Op Code: F3 DC

E