26

Group

Name

Cmd Resp Description

Read /
Write

Min
value

Max
value

Default
value

Values

Index #1

Index #2

SET_USER_GAIN_B

sb

sb

ADC B channel adjustment
(advanced setting)

Rd/Wr 0

255

128

128 = neutral

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SET_PULLDOWN_2_2

Sn

Sn

Enable/disable the auto 2:2
pulldown

Rd/Wr 0

1

1

0 = Disable automatic detection
1 = Enable automatic detection

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SET_PULLDOWN_3_2

Sp

Sp

Enable/disable the auto 3:2
pulldown

Rd/Wr 0

1

1

0 = Disable automatic detection
1 = Enable automatic detection

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12