Analog Way OPS300 Programmer's Guide User Manual

Page 54

Advertising
background image

54

Group

Name

Cmd Resp Description

Read /
Write

Min
value

Max
value

Default
value

Values

Index #1

Index #2

PSTATUS_REFRESH_INTERVAL

Pi

Pi

Time between 2 frames of an
animated logo

Rd/Wr 1

10000 56

Unit = 1ms

1 = Logo 1
2 = Logo 2
3 = Logo 3
4 = Logo 4
5 = Logo 5
6 = Logo 6
7 = Logo 7
8 = Logo 8
9 = Frame 1
10 = Frame 2
11 = Frame 3
12 = Frame 4
13 = Frame 5
14 = Frame 6
15 = Frame 7
16 = Frame 8

LAN

LANENABLE

ne

ne

LAN enable

Rd/Wr 0

1

0

0 = Enable RS232 ( disable LAN )
1 = Enable LAN ( disable RS232 )

LANRESET

nr

nr

LAN factory parameters reset

Rd/Wr 0

1

0

Auto reset

LANSTORE

ns

ns

LAN parameters update

Rd/Wr 0

1

0

Auto reset

LANIP

nw nw

LAN devices addresses

Rd/Wr 0

255

192

IP : 0 to 255

0 = Device
1 = Remote
2 = Gateway

0 = IP address
high byte
1 = IP address
mid high byte
2 = IP address
mid low high byte
3 = IP address
low byte

LANPORT

np

np

LAN port numbers

Rd/Wr 0

65535 10500

Local port : 10000 à 10999
Remote port : 0 à 65500

0 = Device
1 = Remote
2 = Gateway

LANNETMASK

nk

nk

LAN netmask

Rd/Wr 0

24

8

Number of 0bits from the right

LANPROTOCOL

nt

nt

LAN protocol

Rd/Wr 0

1

1

0 = UDP Protocol
1 = TCP protocol
2 = AMX Protocol

Advertising