PT-Basic Programming Manual Ver. 1.00

126/143

Code ID setting

0x00 ~ 0xff ASCII code(1 or 2

bytes)

Parameter1

Parameter2

Alphanumeric Entry

22

Telepen

1

Read

0: Disable *

1: Enable

2

Check-sum verification

0: Disable *

1: Enable

3

Check-sum

transmission

0: Disable *

1: Enable

4

Max. code length

0 ~ 64

0 *

5

Min. code length

0 ~ 64

0 *

6

Truncate leading

0 ~ 15

0 *

7

Truncate ending

0 ~ 15

0 *

8

Code ID setting

<S>

0x00 ~ 0xff ASCII code(1 or 2

bytes)

10

Format

0: Numeric *

1: Full ASCII