Table 2-6, Amc bay b1- port assignments, Hardware preparation and installation – Artesyn ATCA-F120 Installation and Use (August 2014) User Manual
Page 40
Hardware Preparation and Installation
ATCA-F120 Installation and Use (6806800D06J)
40
The AMC interfaces of AMC bay B1 provide support for the following types of AMC modules:
Network security AMCs
Telecom clocking AMCs
Storage AMCs
The following table describes in detail how the AMC ports of Bay B1 are assigned on the ATCA-
F120.
Table 2-6 AMC Bay B1- Port Assignments
Connector Region
AMC Port #
Usage on ATCA-F120
Clocking
1
CH1-CLK1
2
CH1-CLK2
3
PCI Express HCSL 100 MHz clock
Common Options
0
Base Channel switch port 21
1
Fabric channel switch 2 port 17
2
AMC B4 port 2
3
AMC B4 port 3
Fat Pipes
4
AMC B4 port 4
5
AMC B4 port 5
6
AMC B4 port 6
7
AMC B4 port 7
8
Fabric Channel switch 2 port 18
9
Fabric Channel switch 2 port 19
10
Fabric Channel Switch 2 Port 20
11
Fabric Channel Switch 2 Port 16
Extended Option
12
SERDES (1000BaseT on ATCA-F120
face plate)
13
Unused
14
Unused
15
Unused