Thermal Requirements

The minimum airflow requirements for the AdvancedTCA platforms are 13 CFM for the 2.2 GHz
PrAMC-7311 module platforms. This is with a maximum operating temperature limit of 55 °C
(131 °F).

Contact your Artesyn sales representative for current information on the detailed thermal
information including airflow and resistance of the PrAMC-7311.

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

Temperature

+0 ºC (32 °F) to +55 ºC (131 °F) (normal
operation) according to NEBS Standard GR-
63-CORE

-40 ºC (-40 °F) to +70 ºC (158 °F) (may be
further limited by installed accessories)

Temp. Change

+/- 0.25 ºC/min according to NEBS Standard
GR-63-CORE

+/- 0.25 ºC/min

Rel. Humidity

5% to 90% non-condensing according to
Artesyn-internal environmental
requirements

5% to 95% non-condensing according to
Artesyn-internal environmental
requirements

Vibration

0.1 g from 5 to 200 Hz and back to 5 Hz at a
rate of 0.25 octave/minute

5-20 Hz at 0.01 g

2

/Hz

20-200 Hz at -3.0 dB/octave
Random 5-20 Hz at 1 m

2

/Sec

3

Random 20-200 Hz at -3 m/Sec

2

Shock

Half-sine, 11 m/Sec, 30 mSec/Sec

2

Blade level packaging
Half-sine, 6 mSec at 180 m/Sec

2

Free Fall

-

1,200 mm/all edges and corners
1.0 m (packaged) per ETSI 300 019-2-2
(Blade level packaging)
100 mm (unpacked) per GR-63-CORE