5.

LED Indicators

The CD-16,CD-8 microphone console offers general VACIE indicators LED as well as configurable
button status LED.

5.1. General system indicators

The CD-16,CD-8 has three different main LED indicators to show different status of the CD-16,CD-8
and VACIE system: Power, Fault and Evac states.

In order to check for the LEDs condition, every 35 seconds both Fault and Evac blinked once.

Power LED: indicates the presence of power on the CD-16,CD-8.

Fault LED: the fault LED is permanently lit if a fault state in the VACIE system has been engaged.

Evac LED: the Evac LED is permanently lit if a evacuation state in the VACIE system has been
engaged.

5.2. Configurable key status LED

As briefly introduced before, the key configuration of the CD-16,CD-8 depends on the VACIE system
used with it. Please refer to VACIE user manuals to learn more about all the configuration possibilities
offered.

However, independently from the VACIE system, when zone selection key are programmed, the two
zone status LED act as follow:

BUSY LED: indicates the presence an audio event on the corresponding zone or group of zone.

HOLD LED: The HOLD LED indicates the user that the zone is still in an active selection state. When
lit, all next call or music routing will be routed to that zone. Note: Before making any call or any music
routing, make sure that the HOLD LEDs reflect the desired zones selection.

5.3. TALK and ALL CALL/RELEASE LEDs

The CD-16,CD-8 call is activated by the fist microphone switch. The talk LED will reflect the status of
the call.

ALL CALL/RELEASE LED: Will be lit when a all call zone selection is active or when all individual
zone keys have been selected. Will be OFF when the button is used for the release of an all call
selection.
TALK LED:
Will be lit when the user can speak in the microphone and blinking during the
broadcasting of a pre or post chime.

6.

Working with the VACIE System

As stated previously, the key configurations and possibilities depend on the VACIE system connected
to the CD-16,CD-8. However some operations are common to all system.

6.1. Busy zone indication

When a system zone is occupied by an audio broadcasting, the corresponding CD-16,CD-8 zone key
is signalized as busy, the corresponding zone busy LED will lit.