Hearth Requirements

When installing into a masonry fireplace, the hearth must meet Uniform Building Code (UBC) standards.

USA

When installing into a zero-clearance fireplace, the hearth must extend 16” (407mm) to the front and 8”
(204mm) to the sides of the insert. The hearth must provide an R-value (thermal resistance) of 1.19 or
greater.

If the insert is a minimum 2” (51mm) above the combustible floor (carpet, wood, etc.) the hearth must
extend 16” (407mm) in front and 8” (204mm) on both sides of the insert. Hearth must be non-combustible
(cement board, tile, etc.). No R-value (thermal resistance) is required.

CANADA

When installing into a zero-clearance fireplace, the hearth must extend 18” (458mm) to the front and 8”
(204mm) to the sides of the insert. The hearth must provide an R-value (thermal resistance) of 1.19 or
greater.

If the insert is a minimum 2” (51mm) above the combustible floor (carpet, wood, etc.) the hearth must
extend 18” (458mm) in front and 8” (204mm) on both sides of the insert. Hearth must be non-combustible
(cement board, tile, etc.). No R-value (thermal resistance) is required.

Masonry Fireplace Requirements

 Must utilize a positive connection (full reline)
 Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired

prior to installation of the insert.

 Chimney height: 15' (4.5M) minimum; 33' (10M) maximum (measured from base of insert).
 Entire fireplace, including chimney, must meet local building requirements.
 The fireplace insert must be placed on a masonry hearth built to UBC standards.

Non-Combustible Hearth
(min. R-Value 1.19)

Combustible
Flooring

Non-Combustible Spark Protection
(Tile, Cement Board, Steel, etc.)

USA Min. 16" (407mm)
Canada Min. 18" (458mm)

Combustible
Flooring

Min. 2"

(51mm)

USA Min. 16" (407mm)
Canada Min. 18" (458mm)