Listing information 43, Listing label, Small flush wood – Avalon Firestyles Small Flush Hybrid-Fyre User Manual

Page 43

Advertising
background image

Listing

Information

43

© Travis Industries

100-01342

4150521

Listing Label

FOR USE WITH SOLID WOOD FUEL ONLY.

HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHIL-
DREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN

BURNS. SEE NAMEPLATE AND INSTRUCTIONS. KEEP FURNISHINGS AND
COMBUSTIBLE MATERIAL A CONSIDERABLE DISTANCE AWAY. DO NOT
OVERFIRE. IF HEATER OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVER-
FIRING. INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CON-

DITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY. DO NOT USE GRATE OR ELE-
VATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE ONLY WITH FIREBRICK IN
PLACE. OPERATE ONLY WITH DOOR CLOSED. OPEN FEED DOORS TO FEED FIRE ONLY. USE
OF OTHER FUELS MAY DAMAGE THE HEATER AND CREATE A HAZARDOUS CONDITION.

DO NOT REMOVE THIS LABEL

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSTALLATION AND RESTRICTIONS IN YOUR AREA.

SUITABLE FOR USE IN FACTORY-BUILT (Z.C.) FIREPLACES AND MASONRY FIREPLACES.

Report No. 100866529PRT-001

Control No. 4000515

MODEL:

SMALL FLUSH WOOD

with Hybrid-Fyre™

Certified for USA and Canada

SERIAL NO:

CONFORMS TO UL STD 1482; CERTIFIED TO ULC STD S628-1993

FACTORY-BUILT (Z.C.) FIREPLACE OR MASONRY FIREPLACE INSTALLATION

INSERT

A

F

B

D

C

E

HEARTH EXTENSION

MANTEL

COMBUSTUBLE SIDEW

A

LL

COMBUSTIBLE F

ACING

NON-COMBUSTIBLE
FIREPLACE FACING

Minimum Clearance to

Combustibles and Hearth

Requirements

Masonry

Fireplace

Installations

Factory-Built

(Z.C.) Fireplace

Installations

A.
B.

*C.
*D.

*E. (US)

*E. (CAN)

F. (US)

F. (CAN)

11.625 in. / 296 mm

6.25 in. / 159 mm
37.5 in. / 953 mm
37.5 in. / 953 mm

16 in. / 407 mm
18 in. / 458 mm

6 in. / 153 mm
8 in. / 204 mm

11.625 in. / 296 mm

6.25 in. / 159 mm
37.5 in. / 953 mm
37.5 in. / 953 mm

16 in. / 407 mm
18 in. / 458 mm

6 in. / 153 mm
8 in. / 204 mm

* From the base of Fireplace Insert.

Factory-Built (Z.C.) Fireplace installations require a fireplace chimney full re-line. Factory-Built (Z.C.) Fireplace chimney must have a minimum
cross-sectional area of 28.85 square inches / 733 square mm. A non-combustible hearth floor protection is also required that provides a thermal
resistance with an R value equal to 1.19 or greater (see chart above and / or owner’s manual for required sizing details).
Minimum 6 in. / 153 mm diameter Stainless Steel liner, full re-line required.
In Canada; a fireplace insert shall be installed with a continuous chimney liner extending from the fireplace insert to the top of the chimney. A
chimney liner shall be tested for conformance with Class 3 requirements of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or
Factory-Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.
PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturer’s installation and operating instructions. Contact your local
building or fire officials about restrictions and installation inspection in your area. Do not connect this unit to a chimney flue serving another
appliance.

This wood heater contains a catalytic combustor, which needs periodic inspection and replacement for proper operation. Consult owner’s manual
for further information. It is against the law to operate this wood heater in a manner inconsistent with operating instructions in the owner’s
manual, or if the catalytic element is deactivated or removed. CAUTION: the combustor used in this appliance (part no. 174-01111) is fragile and
must be handled carefully. Burning of metal foils, plastic, garbage, sulphur and diesel oil will render the catalyst in the combustor inactive. The
performance and durability of the catalytic combustor has not been evaluated as part of the certification.

Electrical Rating:
Blowers:

115V., 60 Hz, 1.8 Amps
# 228-10069 / 228-10070

Replace glass only with 5mm neoceramic or
ceramic glass.

Do not route power cord under or in front of appliance.

TRAVIS INDUSTRIES, INC.

12521 Harbour Reach Drive

Mukilteo, WA 98275

Manufactured by:

www.travisproducts.com

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020. 0.89 g/h, Method 28, 5G2, 2015

Made in U.S.A.

2015

2016

2017

2018

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

DATE OF MANUFACTURE