5012 delete h8 loader, 5013 prog h8 loader, 5014 power – Avery Dennison Monarch 9864 Error Messages User Manual

Page 38: 5015 scanner, 5016 alx rewinder, 5017 power supply, Delete h8 loader, Prog h8 loader, Power, Scanner

Advertising
background image

05/08 Rev. AB

USER MANUAL

Error Messages

9844 – 9854 – 9864

38

5012

Delete H8 loader

Status

Error while loading the H8 firmware: the old firmware on the machine could
not be deleted.

Action

Press Online to acknowledge.

Reload the firmware.

If the error occurs repeatedly, the bootloader must be reloaded.

5013

Prog H8 loader

Status

Error while loading the H8 firmware: the new firmware could not be written.

Action

Press Online to acknowledge.

Reload the firmware.

If the error occurs repeatedly, the bootloader must be reloaded.

5014 Power

Action

Press Online to acknowledge.

5015 Scanner

Status

Error at the scanner.
The scanner is tested during printer initialization by turning it on for a
moment. A properly working scanner sends a reply signal to the printer. No
signal sends a message.

Action

Press Online to acknowledge.

Is the red scanner LED light on? If not, there is no power. Check if the

scanner connection cable is plugged in correctly and if the connection cable
is damaged.

Is the yellow scanner LED light on shortly after turning on the printer? If not,

the scanner test was faulty.

5016 ALX

Rewinder

Status

The output stage board belonging to the rewinder motor is not connected or
damaged.

Action

Check if the board is connected properly.

Exchange the board to verify if it is damaged.

5017 Power

Supply

Status

Communication fault of the power supply while performing the "Head dot
test".

The power supply did not switch to the dot check mode. Also, the power
supply may have caused disturbances on the processor line. Even if the
switchover is defective (the message is continuously displayed), the printer
can be used in normal operation mode.

Action

Press Online to acknowledge.

Advertising