Start print mode

9864

¯

Only with USI board.

Selecting a print mode. The input signal START_PRINT is interpreted
differently by the USI interface.

Pulse fall/rise

Printing is triggered by a signal change (low-high and high-low) at the input
START PRINT. The printing starts after the set delay time.

Level high active

Labels print when the signal at input START PRINT is held high.

Pulse rising

Printing triggered by a signal change (low-high) at the input START PRINT.
Printing starts after the set delay time.

Level low active

Labels print when the signal at input START PRINT is held low.

Pulse falling

(Default setting) Printing is triggered by a signal change (high-low) at the
input START PRINT. Printing starts after the set delay time.

End print mode

9864

¯

Only with USI board.

Sets how the output signal PRINT_END at the USI interface is handled.
Determines the signal response after printing a label.

Mode 0

No print end signals.

Mode 1

Low when the print module is feeding a label, otherwise high.

Mode 2

High when the print module is feeding a label, otherwise low.

Mode 3

(Default setting) Low for 20 ms after printing and dispensing a label.

Mode 4

High for 20 ms after printing and dispensing a label.

Mode 5

The PRINT_END signal is low when the material is fed forwards (even for
gap initialization).

Mode 6

The PRINT_END signal is high when the material is fed forwards (even for
gap initialization).

Reprint signal

9864

¯

Only with USI board.

Sets how an incoming signal on pin REPRINT\ at the USI is handled.

Disabled

(Default setting) Incoming signal is ignored.

Enabled

On a high-low toggle of the signal: The last printout repeats.