60

#PC

Setting Parameter Values

Setting of parameters in the printer menu to certain values. The function is
helpful, if…

settings must be transferred from one printer to another.

several printers are supposed to have the same settings.

the settings of a printer are supposed to be recovered, e.g. after the CPU

board was replaced.

It is adviseable to read out the parameter settings of the concerned device
at first. This can be done one of the following ways:

With the Easy-Plug command

#!PG

.

By aid of parameter

SPECIAL FUNCTION > Parameter to CF

.

Many of the parameters need a system reset, before the changed setting

becomes effective. This can be triggered at the printers operation panel or
by an Easy-Plug command.

Syntax

#PC<ParameterID>/<Value>#G

Group

H

<ParameterID>

Parameter Ident number (ID)

. Each parameter in the menu has its own

Parameter-ID.

Finding out a Parameter-ID: Call

SPECIAL FUNCTION > Parameter to CF

. The so

generated text file contains the assignment Parameter-ID/Parameter.

999999

= Parameter-ID for special functions; must be applied in

combination with one of the below listed values (Tab. 5).

/

Separation

sign

<Value>

Parameter Value

. The admissible values depend on the type of parameter.

Assigned values can be integer numbers, floating point numbers or strings.

The parameter values for the parameters

IP address

,

Netmask

and

Gateway address

can be specified in the format xxx.xxx.xxx.xxx or as plain

integer.

Further information can be found in the command description of

#!PG

.

Value Function

-1

Reset

1

If the parameter

SPECIAL FUNCTION > Factory settings

is called, the

current parameter settings are used (equals the parameter
setting

SPECIAL FUNCTION > Default values = User defined

)

2

If the parameter

SPECIAL FUNCTION > Factory settings

is called, the

standard factory settings are used (equals the parameter setting

SPECIAL FUNCTION > Default values = Standard

)

Tab. 5 Admissible values for special functions – must be applied together with Parameter-

ID „999999“.

Example

#PC1508/viper#G

Sets the FTP Server password to „viper“
(

INTERF. PARAM. > ETHERNET PARAM. >

FTP password = viper

)

#PC999999/-1#G

The printer will be started newly (reset)