Y./.f./. data exchange, Yb bar code definition, Y./.f – Avery Dennison Monarch 9864 Description of Commands User Manual

Page 90: Data exchange, Bar code definition, For bar codes is re

Advertising
background image

10/07 Rev. AA

MANUAL EASY PLUG

Commands

All

devices

A = TTX 600 --TLX 604 – Eagle B = TTX 300 Offline -- Cobra Offline D = TTX 300 Online –TTX 207 -- Cobra Online – Da Capo
E = TTX 450/650/674/675/950/1050 – Puma/Puma plus/Lion/Lion plus/Tiger/Tiger XXL -- S45/65/95/105 -- TDI/STDI/XXTREME
G = TTX 350 – Ocelot – TTK – Texxtile H = 64-xx –Chess x –TT4 – DPM – PEM – ALX 92x – AP 4.4/5.4

90

Y

#Y./.F./. Data exchange

Function

With the switch <F>, user data outside of the format #ER to #Q/ can be
sent and assigned to the preceding format.

It is not necessary to transfer the entire format if the user data is altered.
Only the position, font and altered user data is sent. Duplicate data is not
sent, which considerably reduces transmission times.

Definition

The switch <F> can be used in conjunction with the commands

#YT

,

#YB

,

#YC

and

#YS

. Switch <F> can be set anywhere between the first two

slashes of the preceding #Y command.

#Y commands marked with <F> are deleted by a following #Y command
outside of the format.

The required position (#J, #T), font number, display options and user data
must be defined with the following #Y command. The quantity must also be
entered.

The command #Y should not be used for printers belonging to the E and G
groups. Use the Variable Data Field command (

#YV

) instead.

Syntax

#Y./.F./.

Groups D, E, G


Example

#!A1
#IMSB100/80
#ERN//
#J5#T10#YT102//// Article number

Data about a label on which the "article
number" also remains constant as fixed
text for subsequent print jobs. The
number designation itself changes after
each print job.

#J5#T30#YT102/F///284-BC
#Q10/#G

Field which is deleted by a following #Y
command outside of the format.

#J5#T30#YT102/F///367-AC
#Q20/#G

The number is changed, all other user
data and information about the label
remain.

#J5#T30#YT102/F///189-ZY
#Q3/#G

Number is changed as before.

#YB

Bar code definition

Definition

This command is used for (optional) parameter settings and entering text.

The decimal position of the check digit must be taken into consideration
with bar codes with a consecutive number (parameter "o").

Command must stand between #ER and #Q!

Syntax

#YBz/dkc/h/s/vo/a/TEXT#G

Groups A, B

#YBz/dkcjfg/h/s/vo/a/TEXT#G

Groups E, G, TTX 300/Cobra Onl.