Electrical Trouble Shooting

Problem

Probable Cause

Corrective Action

Front panel does not

complete diagnostics test
2.

1) One or more PC board(s)

unplugged from the Mother
Board.

1) Power off and remove the power cord from the

AC entry. Remove the back cover and reseat the
offending board.

Machine does not receive

batches.

1) Serial communications cable

loose or unconnected.

1) Check and secure both ends of the serial cable

with the thumbscrews.

2) Machine not powered on or has

not completed diagnostics tests.

2) Power machine on and wait until machine

displays "Ready for batches". Re download data.

3) Data sent to wrong printer.

3) In PCMate change to the printer the data is

intended to be sent.

4) Configuration incorrect in

PCMate.

4) Re configure PCMate for AVERY DENNISON

PCL printer as per your PCMate manual.

5) Faulty Thermal Control Board.

5) Replace Thermal Control Board.

6) Jumpers not configured correctly.

6) Contact AVERY DENNISON Service.