6.11.5

F3 = D iagnostics

The m enu D IA G N O S TIC S includes service functions fortesting sew ing
units,aggregates as w ellas the initiators foractivating the aggregates.

F1 = S ervice test

F1 = M em ory test

F1 = E E P R O M 2K

F2 = E E P R O M 8K

F3 = R A M 8K

F4 = I/O M odule long-term test

F5 = I/O A nalog output

F6 = Furthertests

F1 = R S 232 Test

F2 = I/O A daptertest

F3 = C om m unication test

F4 = S ew ing head test

F1 = A ctivating the sew ing m otor

F2 = S ew ing m otorand puller

F3 = E jector

F4 = Top feed

F5 = D ifferential

F6 = R eference value transm itter

P ress key “P ”.
The program m ing levelis called up.

P ress key “F3”.
The function D IA G N O S TIC S is called up.

C allup the testfunctions.

N ote

These service functions should only be carried outunderthe guidance
ofthe B eislerservice departm entorin cooperation w ith experienced
service personnel.

A ttention:R isk ofbreakage!

D uring the tests individualm achine aggregates orm achine sequences
are started.Ifcom ponents have been disassem bled com pletely or
partially orifthey are notoperational,m achine com ponents m ay be
dam aged.
M ake a testonly w hen the m achine is ready foroperation.

F1 = S ervice test/F1 = M em ory test

A TTE N TIO N !

A lldata in the m em ories are deleted.

F1 = E E P R O M 2K

F2 = E E P R O M 8K

F3 = R A M 8K