Unit Connections and Dimensions

2-10

2.5.4

Serial I/O (Remote)

The DP570 will allow remote control via the front-panel (RS-232) or rear-panel (RS-
485) ports. See Section 6.4 for further information. The serial I/O connections can
also used for software upgrades.

2.5.5

General Purpose I/O

The DP570 has a 37-pin female D-connector for the GPI/O connections. Most of
these connections are user definable, but there are a few standard connections.

Table 2-6 Pin Connections for the Cat. No. 548 Analog Option Card Stereo/Mono Output

Pin

Function

Pin

Function

1

+5 V (150 mA)

7-19

User Defined Outputs

2

Fault Output

20

Encoder A Input

3

Error Output

21

Encoder B Input

4

User Defined Output

22

Encoder Present Input

5

Solo Tally Output

23-36

User Defined Inputs

6

Solo Control Input

37

Digital ground

2.5.6 Metadata

Inputs

The metadata input ports are RS-485 ports. These can be used for the input of
metadata from a DP572 or other metadata source. See Section 5.2 for pin
assignments.

2.5.7 Metadata

Output

The metadata output port is an RS-485 port. This can be used for the output of
metadata to a DP569, DP571, or other unit with metadata input. See Section 5.2 for
pin assignments.

2.5.8 10BASE-T

This port will be implemented in future versions.

Advertising