Dolby Installation Guidelines

Unit Connections and Dimensions

2-13

Table 2-9 Preset Mode Tally Indication on Status Port

Pin 7 Transition

Pin 8 Transition

Preset

High-to-Low

None or Low-to-High

1

None or Low-to-High

High-to-Low

2

High-to-Low High-to-Low 3

2.6.7 Auxiliary

Data

The Auxiliary Data port is a 9-pin female RS-232 port that may be used for future
enhancements. See Section 5.2 for pin assignments.

2.6.8 Metadata

Input

The metadata input port is an RS-485 port. This can be used for the input of metadata
from a DP572 or other metadata source. See Section 5.2 for pin assignments.

2.6.9 10BASE-T

This port will be implemented in future versions.

2.7

DP572

Figure 2-7 Front and Back Panels of the DP572

2.7.1 Dimensions

The DP572 occupies one rack unit and measures 44

Ч

483

Ч

324 mm (1.75

Ч

19

Ч

12.75 inches). Its net weight is approximately 2.7 kg (6.0 lb).

2.7.2 Audio

Connections

The main input is provided on a female BNC connector. The inputs should be
compliant with AES3-id-1995 (unbalanced, 75

, 1V peak-to-peak standard output).