Stx z - print internal information, Stx z - pack module, Stx b - set cutter signal time – Datamax DGL User Manual

Page 32: Stx c - copy module, Stx d - memory dump (test mode only), Stx d - set printer to double buffer mode, Stx g - internal batch software mode, Stx n - enter internal batch, Stx s - set printer to single buffer mode, E - recall printer configuration

Advertising
background image

32

Chapter

3

received, the printer will respond with the internal A-D sensor values, see
table below. To repeat the display of values, send the printer a ‘SPACE’ (20
hexadecimal). Send <ESC> to terminate the function.

(Not supported.)

STX Z - Print Internal Information

This command prints the configuration. To capture all printed information, use
labels as wide as the print width and at least 4 inches (102mm) long.

(Not

supported.)

STX z - Pack Module

This command causes the printer to reclaim all storage space associated with
all deleted files on the specified module. A Flash Module cannot be packed.
(Not supported.)

STX b - Set Cutter signal time

(Obsolete System Command.)

STX C - Copy Module

(Obsolete System Command.)

STX D - Memory Dump (Test Mode Only)

(Obsolete System Command.)

STX d - Set Printer to double buffer mode

(Obsolete System Command.)

STX g - Internal Batch Software Mode

(Obsolete System Command.)

STX N - Enter Internal Batch

(Obsolete System Command.)

STX s - Set Printer to single buffer mode

(Obsolete System Command.)

e - Recall Printer Configuration

This command recalls a previously stored printer configuration. It is highly
recommended that only one Recall Printer Configuration command be used
per label, and that it be used at the beginning of the label; otherwise,
unpredictable results will occur. (Printer Configurations may be stored using
the Extended System Commands or the printer’s menu system.)

(Not

supported.)

Advertising