DATA REQUIRED,

(Programming Irregular Shapes)

T

o program a completely new shape (Press “A”).

Count the number of segments or operations and enter the total.

For each segment, enter the following:

TYPE:

Select digit keys 1-8

QUADRANT:

1, 2, 3, or 4 (refer to Programming Segment Chart)

SIZE:

One or more dimensions per segment as described below:

100 X inch or 10 X mm (depending on the machine version):

or for time, 100 X second of delay.

(E.g. 150 = 1.5", or for metric 375 = 3

7.5mm)

DESCRIPTION OF SEGMENT TYPES (Refer to Programming Segment Chart)

TYPE 1:

Clockwise, 90-degree arc segments.

Quadrant determined by which quarter of a full circle makes the arc.

Dimensions required: Radius only.

TYPE 2:

Counter-clockwise, 90-degree arc segments.

Quadrant determined by which quarter of a full circle makes the arc.

Dimensions required: Radius only.

TYPE 3:

Line along X or Y-axis.

Quadrant determined by direction of movement.

(East: 1, North: 2, West: 3, South: 4).

Dimensions require length only.

TYPE 4:

Angled straight line.

Quadrant determined by direction of movement.

(Northeast: 1, Northwest: 2, Southwest: 3, Southeast: 4).

Dimensions required:

1. X-dimension, movement along the X-axis

2. Y-dimension, movement along the Y-axis

TYPE 5:

Function or Operation.

Quadrant determined by function selected.

1. WELD / OXYGEN “ON”: turns on the contact relay or oxygen solenoid.

Dimensions required: None.

2. WELD / OXYGEN “OFF”: turns off the contact relay or oxygen solenoid.

Dimensions required: None.

3. PAUSE: Machine stops and waits until START / RESUME button is pushed.

Dimensions required: None.

4. DELAY: Machine stops and holds position for a programmed period of

time up to 99.99 seconds.

Dimensions required: time in .01 second units. (E.g. 250 for 2.5 seconds)